image

MP-1015 Multi Purpose Horizontal Electrophoresis System

Model Number IB53000

$675.93

High-Performance Horizontal Electrophoresis System

IBI’s MP-1015 Multi-Purpose Gel Box (10 x 15 cm) is a general-purpose unit designed for both extended high-resolution linear runs and economical quick screens. This Horizontal Electrophoresis system is equipped with recirculation ports for procedures requiring buffer recirculation. The MP-1015 IBI electrophoresis unit is constructed of durable cast acrylic, ensuring it withstands high voltages and extreme temperatures without cracking or warping, unlike most molded units.

  • Item Description
  • Product Video
  • Specifications
  • Operation Manual
  • Technical Information
  • Parts and Accessories
  • Combs

Additional Item Description:        

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the MP-1015 is 140 V. In a 1% TBE gel this translates into a run time of approximately one hour. Lower voltages may be used and as a general rule a 70 V run will take twice as long as a 140 V run. Higher voltages may be used to decrease run time. However, if the unit is being operated at higher voltages than 140 V the heat generated during electrophoresis may decrease sample resolution. Such artifacts may be avoided by running the unit in a cold room, recirculating buffer, or adding 1 X electrophoresis buffer “ice cubes” to keep the unit properly cooled. The suggested run parameters for the electrophoresis of RNA in agarose gels containing formaldehyde is 60-80 V.

How to Replace Tank Connector:


How to Replace Electrode Assembly:


Physical Specifications:

Unit dimensions: 7.0 cm (H) x 16.5 cm (W) x 30.5 cm (L)
Gel Dimensions: 10 cm (W) x 15 cm (L)
Max Sample Capacity: 80 samples (4 combs x 20 samples ea.)
Buffer Capacity: 500 ml
Distance between electrodes: 27.0 cm
Max volt.: 200 V

Operation Manual Link:

IB53000 - MP-1015 Operation Manual

Characteristics of Horizontal Electrophoresis Units:

IBI horizontal systems are constructed of 3/8” thick cast acrylic, the heaviest in the industry. No warping occurs when the system gets hot, and there are no crazy cracks in the plastic after time. The buffer tank on the IBI systems can be completely re-built, by the end user, in minutes. IBI horizontal systems have a 4-year limited warranty on the buffer tank. IBI horizontal systems allow the user to cast gels OUTSIDE the buffer tank, this is much easier and allows user to cast a gel while a gel is running. IBI systems are 20% less expensive and come with casting system and combs. This info applies to all of IBI horizontal systems against nearly all of our other competitors systems.

Does doing longer runs with the IB53000 flood the table with water?

This is a common occurrence while running longer runs. There is heat generated from the electricity flowing through the buffer, which causes the buffer to condensate on the underside of the lid then subsequently run outside the tank. If the tank was leaking, it would have leaked continuously, before the long run. This device when left unattended, the researcher will assume the researcher comes back they find the wet spots around the unit and assume that it’s leaking. This is probably the reason for the excess water. Hope this helped.

Combs Link:

MP-1015Combs

25% off your order

Enter your email address to get 25% off your order and free shipping today

image